Responsive Navbar

TATA Roof Deck D100 offers a 700mm cover width

PLAIN Galvanised as standard or MAGNELIS OR COLOURCOAT FD finishes available on request for aggressive environments.

Image

Nationwide delivery

Image

24 hour delivery

Image

24 hour support

TATA ROOF DECK D100

The TATA RoofDek D100 is a robust, deep trapezoidal metal decking profile designed primarily for long-span roofing applications and is ideal for projects requiring superior load-bearing capabilities and extended spans.

Capable of spanning up to 6.0 metres through the effective use of overlapping sheets, making it ideal for large commercial spaces and warehouses where wide, open interiors are essential.

This profile is designed to support heavy loads, with typical loadings reaching up to 4.0 kN/m², while maintaining a lightweight structure.

Watch this short video for a quick explanation!

  • The D100 gives excellent acoustic insulation, enhanced by perforated edges and profile fillers to reduce noise transmission — particularly beneficial in urban environments.

  • A versatile profile is available in both plain and factory-perforated acoustic versions, offering an excellent combination of structural strength, stiffness, and sound absorption.

  • Perforated web roof decking to provide acoustic absorption, acoustic reduction and structural support.

  • Capable of spanning up to 6.0 metres through the effective use of overlapping sheets, making it ideal for large commercial spaces and warehouses where wide, open interiors are essential. This profile is designed to support heavy loads, with typical loadings reaching up to 4.0 kN/m², while maintaining a lightweight structure.

  • With greater environmental sustainability, the D100 is recycleable - friendly.

  • Easy to handle for safer onsite logistics.

  • Compliance with Design Codes and Standards (see technical)

  • High acoustic and sound insulation, even with reduced concrete volume.

DESIGNED FOR

CONSTRUCTION PROJECTS

Features

RoofDek D100 Profile Depth: 100 mm

Cover Width: 700 mm

Profile Type: Deep trapezoidal profile optimised for long spans

Variants: Plain steel or factory-perforated acoustic options

RoofDek D100 Steel Grade: Typically S320GD+Z (high-strength, galvanised steel)

Minimum Support Flange Width: 100 mm

Perforation Pattern: 4.5 mm diameter holes arranged in a 6.3 mm triangular pitch

Open Area: Approximately 46% (used for calculating acoustic exposed area and cover area)

RoofDek D100 Finishes Available: Plain galvanised steel (standard)

Colorcoat HPS200 Ultra® (single- or double-sided, depending on gauge)

Other finishes available upon request (subject to minimum order quantities)

Aluminium Variants: Available on request (subject to MOQ)

Benefits

RoofDek D100 Acoustic Performance

The RoofDek D100 profile can be supplied with factory-applied perforations to enhance sound absorption, making it suitable for buildings requiring effective noise control.

Sound Absorption Class: Ranges from A to D, depending on the chosen liner and insulation system.

Exposed Area (EA): Ratio of perforated area to total steel surface area.

Cover Area (CA): Ratio of perforated area to soffit footprint.

These acoustic parameters enable engineers and acoustic consultants to confidently design roofing systems that meet stringent noise control requirements. For detailed acoustic reports and design advice, please contact the RMD Profiles technical team.

Applications

It is ideal for use in schools, industrial facilities, stadiums, commercial buildings, and other projects where acoustic performance and durability are critical.

TECHNICAL SPECIFICATION

Technical

Compliance with Design Codes and Standards

The RoofDek D100 complies with the following:

Eurocode 3 (EN 1993-1-3): Cold-formed steel structural design

Eurocode 9 (EN 1999-1-4): Aluminium structures (where applicable)

SCI P359: Fire performance design guidelines

ISO 11654: Acoustic absorption ratings

BS 5950-6:1995: British Standard for profiled steel sheeting (noting that Eurocode generally allows mesh reinforcement while BS 5950 requires bar reinforcement in troughs)

Steel Construction Institute (SCI) P300: Good practice for metal decking design

RMD Profiles can assist with both Eurocode and British Standard compliant designs to suit your project requirements.

For more technical information, click here or download the product datasheet.

ENQUIRY HERE

9 Gaol Lane, Sudbury, Suffolk, CO10 1JL

Monday - Friday 7.30am - 4.00pm

Saturday - Sunday - CLOSED

Copyright © 2024 RMD Profiles | Powered by Genie AI